RIVERTRACE ENGINEERING (RTE) SMART 50M

RIVERTRACE ENGINEERING (RTE) SMART 50M

Multiple optical sensors measure the combination of light absorbed and scattered by oil droplets in the sample stream. The sensor signals are read by a microprocessor which uses sophisticated algorithms to determine the concentration of oil and solids in the stream. The oil concentration is displayed on an alphanumeric display. A microprocessor drives a 4-20 mA current loop output representing the oil concentration. Two volt-free alarms are driven when the oil concentration exceeds the set points. An Autoclean system is included to ensure the accuracy of the optical measuring system is maintained over extended periods of operation.

 

The microprocessor also measures various other parameters to determine the condition of the system to ensure that accuracy is maintained over time and various environmental conditions. A log of alarms and faults is stored on the system for maintenance purposes.

 

A contact closure and remote start-stop facility are included to enable sample conditioning when used as part of a system. Three optional parameters can be displayed; these are PH, conductivity and oxygen concentration. Remote monitoring is available via HART or Modbus. A menu-driven system allows the operator to set or display various conditions via the keypad. HART is a registered trademark of the HART Communication Foundation.

More About RIVERTRACE ENGINEERING (RTE) SMART 50M

Ranges:

Large cell: 0 – 10 ppm

Medium cell: 0 – 200 ppm

 

Accuracy:

Large cell: +/- 0.15 ppm

Medium cell: +/- 2 ppm

 

Resolution:

Large cell: 0.1 ppm

Medium cell: 1 ppm

 

Alarm 1 Operating Point:

Large cell: 1 – 10 ppm

Medium cell: 10 – 200 ppm

 

Alarm 2 Operating Point:

Large cell: 1 – 10 ppm

Medium cell: 10 – 200 ppm

Alarm 1 operating delay: 1-15 seconds

Alarm 2 operating delay:1-600 seconds (and alarm2 off)

Alarm contact rating: 5 AMP

Alarm relay mode: De-Energised in Alarm State

Output signal: 4-20 mA

Projected Life (Electronics): > 50,000 Hours

Ambient temperature: 1-50 °C

Humidity: Max 98% non-condensing

Sample temperature: 1-95 °C

Sample Flow: 0.3 to 3 Ltrs/Min

Sample Pressure: 0.1-10 Bar

Clean Water requirements: Ask for a sample

Weight: 15Kg

Size: 500 x 360 x 150mm

Supply voltage: 110/220 v a.c

Supply variation: 10% of nominal voltage

Supply frequency: 50/60 Hz

Power consumption: 15 VA

Degree of Protection: IP56

More Products

Mr. Marine Products
PORTABLE GAS DETECTOR RKI GX-2009
Mr. Marine Products
MT.H CONTROL VALVES: PNEUMATIC PRESSURE OR TEMPERATURE CONTROLLER
Mr. Marine Products
MT.H CONTROL VALVE: PNEUMATIC DIAPHRAGM TYPE VALVE
Mr. Marine Products
MT.H CONTROL VALVES: PNEUMATIC ACTUATOR 3-WAY ROTARY VALVE
Mr. Marine Products
MT.H CONTROL VALVES: ELECTRIC PRESSURE AND TEMPERATURE CONTROLLER
Mr. Marine Products
MT.H CONTROL VALVES: ELECTRIC PNEUMATIC PRESSURE OR TEMPERATURE CONTROLLER
Mr. Marine Products
MT.H CONTROL VALVES: ELECTRIC ACTUATOR 3-WAY VALVE

Enquiring about

RIVERTRACE ENGINEERING (RTE) SMART 50M