Tyco MZX-c+ Conventional Fire Detection Control Panels

Tyco MZX-c+ Conventional Fire Detection Control Panels

The Tyco MZX-c+ range offers conventional fire detection control panels that prioritize ease of installation and use. These panels are highly flexible and programmable, allowing for customization without the need for additional configuration software. The range includes panels with 4, 8, 16, and 32 zones, as well as repeaters and various expansion modules. The 4, 8, and 16 zone models share a common housing, while the 32 zone panel comes in a larger enclosure. The repeater panels are equipped with built-in 240Vac power supplies, with the 8 zone repeater compatible with both the 4 and 8 zone panels. All units in the range are designed and manufactured to meet the highest standards and are approved according to EN54 parts 2 and 4.

Key features of the Tyco MZX-c+ Conventional Fire Detection Control Panels range include support for 4, 8, 16, and 32 zone configurations, the option for semi-flush mounting using an optional bezel, compatibility with a wide range of EN54 approved Series 600 detectors (including photo multi-sensor and CO multi-sensor), and compatibility with the System 620 ATEX and IECEx approved intrinsically safe system. The panels offer extensive customization options, which can be programmed using switches and front panel controls. Additional features include two-stage alarms, investigate delay options, day/night modes, alarm counters (with an optional timer module), full EN54 zone operation with various circuit options, and inputs for remote Silence, Evacuate, Reset, and Class change. Overall, the MZX-c+ range of conventional fire detection control panels offers versatility, quality, and adherence to safety standards for various fire detection applications.

More About Tyco MZX-c+ Conventional Fire Detection Control Panels

Features:

› 4, 8, 16 and 32 zone versions available

› Semi-Flush mounting using an optional bezel

› Supports the complete range of EN54-approved Series 600 detectors including photo multi-sensor and

› CO multi-sensor

› Compatible with System 620 ATEX and IECEx approved intrinsically safe system

› Extensive custom options programmable via switches and front panel controls

› Two-stage alarms and investigate delay options

› Day/Night modes and alarm counter (with optional timer module)

› Full EN54 zone operation with options for non-latching, short circuit alarm or indication only circuits

› Inputs for remote Silence, Evacuate, Reset and Class change

› Configurable monitored or volt-free outputs for Fire, Fault and Protection

› Outputs for zones 1 to 4 (open collector) with 8, 16 or 32 zonal outputs provided by optional expansion boards

› Outputs for Disablement active, Evacuate active and buzzer active (open collector)

› Volt-free reset relay. Active for 10 seconds following a panel reset

› 8 to 32 zone systems can drive up to 12 expansion input/output modules per panel

› Drive up to 5 repeater panels

.

Ancillaries and Expansion:

A number of interface and expansion modules are available to provide the necessary ports and input/output capability required for more demanding and complex conventional schemes.

 

C1631 Repeater Interface Board provides an RS485 port for driving up to 5 repeater panels. One C1631 Repeater interface board is required for the panel and one for each repeater. Repeaters are supplied with a C1631 fitted.

 

C1630 Output Expansion Interface Board provides an RS485 port for driving up to 12 output expansion boards.

 

EXP 4 and EXP 4 PSU Expansion Housing are designed to house any combination of up to four output expansion boards. The PSU version is equipped with a 5A 24Vdc power supply and space for 2 x 12V 12Ah batteries.

 

EXP 5 and EXP 5 PSU Expansion Housing are similar to EXP 4 and EXP 4 PSU but accommodate five output expansion boards.

 

C1633 LED Driver Board provides eight open collector outputs rated @ 60mA. Outputs can be a zonal alarm or a common alarm.

 

C1634 Relay Output Module provides eight-volt free changeover contacts rated at 1A 30Vdc. Outputs can be a zonal alarm or a common alarm.

 

C1635 Monitored Output Board provides eight fault monitored 24Vdc outputs. Power can be derived from the control panel or an external source. Outputs can be a zonal alarm or a common alarm.

 

C1651 MZXC+ Timer Module is an optional plug-in board with an alphanumeric LCD to provide a real-time clock display. The clock can be programmed to provide investigate delays and day and night settings. The unit is also used to store and display a total count of the number of times the panel enters the alarm condition. This unit can be fitted to 8, 16 and 32 zone panels.

More Products

TPI 721 Combustible Gas Leak Detector
TPI 721 Combustible Gas Leak Detector
TPI 720b Combustible Gas Leak Detector
TPI 720b Combustible Gas Leak Detector
TPI 719 Combustible Gas Detector
TPI 719 Combustible Gas Detector
TPI 777 Personal CO Gas Monitor
TPI 777 Personal CO Gas Monitor
TPI 775 Carbon Monoxide & Combustion Gas Detector
TPI 775 Carbon Monoxide & Combustion Gas Detector
TPI 770 Carbon Monoxide Monitor
TPI 770 Carbon Monoxide Monitor
TPI 9085 Smart Vibration Analyzer
TPI 9085 Smart Vibration Analyzer
TPI 9084 Smart Vibration Analyzer
TPI 9084 Smart Vibration Analyzer

Reach us

Product Enquiry

Tyco MZX-c+ Conventional Fire Detection Control Panels

Product Service Enquiry

Tyco MZX-c+ Conventional Fire Detection Control Panels